Sign In | Join Free | My himfr.com
Home > Fluorescence Immunoassay Test >

cTnT Cardiac Troponin T Test Kit In Human Blood Serum Plasma

Hangzhou AllTest Biotech CO.,LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap cTnT Cardiac Troponin T Test Kit In Human Blood Serum Plasma from wholesalers
     
    Buy cheap cTnT Cardiac Troponin T Test Kit In Human Blood Serum Plasma from wholesalers
    • Buy cheap cTnT Cardiac Troponin T Test Kit In Human Blood Serum Plasma from wholesalers

    cTnT Cardiac Troponin T Test Kit In Human Blood Serum Plasma

    Ask Lasest Price
    Brand Name : FIATEST
    Model Number : FI-CTI-402
    Certification : CE
    Price : negotiation
    Payment Terms : L/C, T/T
    Supply Ability : 10 M tests/month
    Delivery Time : 2-4 Weeks
    • Product Details
    • Company Profile

    cTnT Cardiac Troponin T Test Kit In Human Blood Serum Plasma

    Cardiac Troponin T(cTnT) Test Cassette,Test Use By fluorescence Immunoassay Analyzer In Human WB/S/P


    Cardiac Troponin T(cTnT) Test Cassette in whole blood /serum /plasma with the use of Fiatest TM fluorescence Immunoassay Analyzer. For professional in vitro diagnostic use only.
    Product Name:Cardiac Troponin T(cTnT) Test Cassette,Test Use By Fluorescence Immunoassay Analyzer In Human WB/S/P
    Format:Cassette
    Certificate:CE
    Pack:10T/25T
    Shelf Life:2 Years
    Principle:Fluorescence Immunoassay
    Specimen:WB/S/P
    Reading Time:15 Minutes
    Storage Temperature:4-30℃
    Cut-Off:0.5 Ng/mL

    Application And Description:


    The Cardiac Troponin T Test Cassette is intended for in vitro quantitative determination of human cardiac Troponin T in whole blood, serum or plasma as an aid in the diagnosis of Myocardial Infarction (MI).The test result is calculated by Fluorescence Immunoassay Analyzer.

    How to use?


    Refer to Fiatest TM Fluorescence Immunoassay Analyzer Operation Manual for the complete instructions on use of the Test. The test should be conducted at room temperature.
    Allow the test, specimen, buffer and/or controls to reach room temperature (15-30 °C) prior to testing.
    1. Turn on the Analyzer power. Then according to the need, select “standard test”or“Quick test” mode.
    2. Take out the ID card and insert it into the Analyzer port.
    3. Serum/plasma: Transfer 75μL serum/plasma into the buffer tube, mix the specimen and the buffer well.Whole blood: Transfer 75μL whole blood into the buffer tube with pipette; mix the specimen and the buffer well.
    4. Add diluted specimen with a Pipette: Pipette 85μL diluted specimen into the sample well. Start the timer at the same time.
    5. There are two test modes for Fiatest TM Fluorescence Immunoassay Analyzer, Standard Test mode and Quick Test mode. Please refer to the user manual of Fiatest TM Fluorescence Immunoassay Analyzer for details.
    “Quick test” mode: Insert the test cassette into the Analyzer at 15 minutes after sample application and click "New test ", the Analyzer will automatically give the test result after a few seconds.
    “Standard test” mode: Insert the test cassette into the Analyzer immediately after sample application, click "New test" at the same time, the Analyzer will automatically count down 15 minutes. After the countdown, the Analyzer will give the result at once.
    The Cardiac Troponin I Test Cassette (Whole Blood/Serum/Plasma) is a simple test that utilizes a combination of anti-cTnI antibody coated particles and capture reagent to detect cTnI in whole blood, serum or plasma.
    INTERPRETATION OF RESULTS

    Results read by Fiatest TM Fluorescence Immunoassay Analyzer.
    The result of tests for HbA1c is calculated by Fiatest TM Fluorescence Immunoassay Analyzer and display the result on the screen. For additional information, please refer to the user manual of Fiatest TM Fluorescence Immunoassay Analyze.
    Linearity range of Fiatest TM HbA1c Test is 0.1-40 ng/mL.
    PRODUCT FEATURES

    【PERFORMANCE CHARACTERISTICS】

    1. Accuracy

    The test deviation is ≤±15%.

    2. Sensitivity

    The Cardiac Troponin T Test Cassette can detect levels of Cardiac Troponin T as low as 0.2ng/mL whole blood, serum or plasma.

    3. Detection range

    0.2~40 ng/mL

    4. Linearity range

    0.2~40 ng/mL , R≥0.990

    5. Precision

    C.V. ≤15%


    Fast Result (15 minutes)

    Simple Operation (Less Training Required)

    Objective (Results Read by Analyzer)

    Stringent Quality Control Insure High Accuracy

    User-friendly (Simple Plug & Play Operation)

    High Efficiency (Both STAT Testing and Batch Testing)



    Catalogue NumberItem NameSampleTest RangeKIT size
    FI-CTNT-402cTnI Test CassetteWB/S/P0.1-40 ng/mL

    10T/25T


    Quality cTnT Cardiac Troponin T Test Kit In Human Blood Serum Plasma for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Hangzhou AllTest Biotech CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)